top of page

TDLAS / OGI Specifications

01

Detectable Gases

02

Specifications

  • Benzene - 3.5 g / hr

  • Ethanol - 0.7 g / hr

  • Ethylbenzene - 1.5 g / hr

  • Heptane - 1.8 g / hr

  • Hexane - 1.7 g / hr

  • Isoprene - 8.1 g / hr

  • Toluene - 3.8 g / hr

  • Methanol - 3.8 g / hr

  • MEK - 3.5 g / hr

  • Pentane - 3.0 g / hr

  • Xylene - 1.9 g / hr

  • Butane - 0.4 g / hr

  • Ethane - 0.6 g / hr

  • Methane - 0.75 g / hr

  • Propane - 0.4 g / hr

  • Ehylene - 4.4 g / hr

  • Propylene - 2.9 g / hr

  • MIBK - 2.1 g / hr

  • Octane - 1.2 g / hr

  • 1-Pentene - 5.6 g / hr

  • Detector Array: Cooled MWIR InSB

  • Pixel Pitch: 15pm

  • FOV: Lens Dependent

  • Measurement Distance: Lens Dependent

  • Pixel Resolution: 640 x 512

  • Spectral Band: 3.2 pm - 3.4 pm

  • Frame Rate: 30 Hz P-Series Optional: 9 hz

  • Detection Distance: 0.5 m (1.6') - 50 m (164')*

  • Minimum Resolution: 1 ppm

  • Response Time: 0.5 seconds

  • Humidity: 5% to 95% non-condensing

  • Pixel Operability: > 99%

  • Video: NTSC or PAL

  • Shutterless