TDLAS / OGI Specifications
01
Detectable Gases
02
Specifications
-
Benzene - 3.5 g / hr
-
Ethanol - 0.7 g / hr
-
Ethylbenzene - 1.5 g / hr
-
Heptane - 1.8 g / hr
-
Hexane - 1.7 g / hr
-
Isoprene - 8.1 g / hr
-
Toluene - 3.8 g / hr
-
Methanol - 3.8 g / hr
-
MEK - 3.5 g / hr
-
Pentane - 3.0 g / hr
-
Xylene - 1.9 g / hr
-
Butane - 0.4 g / hr
-
Ethane - 0.6 g / hr
-
Methane - 0.75 g / hr
-
Propane - 0.4 g / hr
-
Ehylene - 4.4 g / hr
-
Propylene - 2.9 g / hr
-
MIBK - 2.1 g / hr
-
Octane - 1.2 g / hr
-
1-Pentene - 5.6 g / hr
-
Detector Array: Cooled MWIR InSB
-
Pixel Pitch: 15pm
-
FOV: Lens Dependent
-
Measurement Distance: Lens Dependent
-
Pixel Resolution: 640 x 512
-
Spectral Band: 3.2 pm - 3.4 pm
-
Frame Rate: 30 Hz P-Series Optional: 9 hz
-
Detection Distance: 0.5 m (1.6') - 50 m (164')*
-
Minimum Resolution: 1 ppm
-
Response Time: 0.5 seconds
-
Humidity: 5% to 95% non-condensing
-
Pixel Operability: > 99%
-
Video: NTSC or PAL
-
Shutterless
03
Fast, Effective and Affordable
Reach out to our experts today about flying OGI or TDLAS Gas Detection technologies to identify problem areas. Valve yards, Pipelines, Compressor stations, tank farms and more. We are here to help.
04
Applications:
-
Petrochemical (Midstream)
-
Gas Leak Detection
-
Pipeline Inspections
-
Industrial Monitoring
-
Petrochemical Monitoring
-
Process Control
-
Scientific Research
-
Landfills
-
Storage Tanks / Tank Farms
-
Valve Yards or Compressor stations